- Direct drive, zero backlash Every joint is driven directly, with no gearbox or tendon between motor and finger, so the force the controller reads is the force the finger applies.
- Visuo-tactile fingertips All five fingers carry visuo-tactile sensors, read through Xynova's VBTS SDK in C++ or Python.
- 1 kHz bandwidth, 0.1 s grip Millisecond-level response gives a controller authority over each finger, and the hand closes a grip in 0.1 s.
- 0.2 N backdrive force The fingers yield to a light push, which protects people and objects and keeps hand-guided teleoperation smooth.
- 22 DoF at human size The 1:1 biomimetic hand is 190 mm long, so tools and objects made for people fit it.
- 20 N fingertips, 20 kg lift The transparent drive keeps real strength: 20 N at each fingertip and up to 20 kg lifted.
Description
The Xynova Prima 1 is a fully direct-drive dexterous robot hand with 22 degrees of freedom, built by Xynova as a measuring instrument for manipulation research. Every joint is driven directly, with no gear train or tendon between motor and finger, and the hand matches a human hand 1:1 at 190 mm.
Removing the transmission removes backlash and the friction that distorts force readings, so what the controller reads is what the finger applies; Xynova describes it as distortion-free force transmission. For a lab training manipulation models on its own data, that makes recorded force usable as a training signal. A 1 kHz response bandwidth gives millisecond authority over each finger, a grip closes in 0.1 s and positions repeat within ±0.5 mm, with native hybrid force and position control.
All five fingers carry visuo-tactile sensors, read through Xynova's VBTS SDK in C++ or Python. The fingers yield to an external push of 0.2 N, which protects people and objects and keeps hand-guided teleoperation natural, yet each fingertip pushes with 20 N and the hand lifts up to 20 kg. Xynova supplies the Prima 1 SDK for Linux on x86_64 and ARM64, Prima 1 Studio for Windows with glove teleoperation and a URDF model; weight, interface, supply voltage and hand side are confirmed with the quotation.
Its sibling, the Xynova Flex 2, uses hybrid tendon and linear-actuator drive across 23 degrees of freedom and is rated for millions of cycles in daily work. Compare both with the rest of our dexterous robotic hands.
Key Capabilities
- Direct drive, zero backlash: Every joint is driven directly, with no gearbox or tendon between motor and finger, so the force the controller reads is the force the finger applies.
- Visuo-tactile fingertips: All five fingers carry visuo-tactile sensors, read through Xynova's VBTS SDK in C++ or Python.
- 1 kHz bandwidth, 0.1 s grip: Millisecond-level response gives a controller authority over each finger, and the hand closes a grip in 0.1 s.
- 0.2 N backdrive force: The fingers yield to a light push, which protects people and objects and keeps hand-guided teleoperation smooth.
- 22 DoF at human size: The 1:1 biomimetic hand is 190 mm long, so tools and objects made for people fit it.
- 20 N fingertips, 20 kg lift: The transparent drive keeps real strength: 20 N at each fingertip and up to 20 kg lifted.
This model is offered on a quotation basis. Configuration, accessories, integration scope and delivery schedule all change the final figure, so pricing is confirmed per project rather than listed.
Buying through Robotix Market
This unit is sourced new through established distribution channels and ships worldwide with the manufacturer warranty. Technical support is coordinated with the manufacturer's own service network. Deployment scope, configuration, and commissioning responsibilities are agreed as part of the quotation — on-site installation is not included in the product price.
Features
Specs
| Brand | Xynova |
|---|---|
| Model | Prima 1 |
| Fingers | 5 |
| Degrees of freedom | 22, biomimetic configuration |
| Drive | Fully direct drive, zero backlash |
| Hand size | 190 mm, 1:1 human hand |
| Maximum fingertip force | 20 N |
| Lifting payload | Up to 20 kg |
| Repeatability | ±0.5 mm |
| Grip time | 0.1 s |
| Response bandwidth | 1 kHz |
| Minimum backdrive force | 0.2 N |
| Tactile sensing | Visuo-tactile sensors in all five fingers |
| Control | Native hybrid force and position control |
| Software | Prima 1 SDK for Linux (x86_64, aarch64); visuo-tactile (VBTS) SDK in C++ and Python; Prima 1 Studio for Windows with glove teleoperation; URDF model |
| Weight | Confirm at quote |
| Control interface | Confirm at quote |
| Supply voltage | Confirm at quote |
| Hand side | Confirm at quote |
| Robot mounting | Confirm at quote |
Industries
Frequently Asked Questions
It is offered by quotation — configuration, quantity and delivery are confirmed per project.
Gears and tendons add backlash and friction between motor and joint, so the force a controller reads differs from the force at the finger. With direct drive at every joint, recorded force data reflects the contact, which makes it usable as training data.
Visuo-tactile sensors in all five fingers. Xynova's VBTS SDK, in C++ and Python, reads them for learning-based control.
Each fingertip pushes with up to 20 N and the hand lifts up to 20 kg. It closes a grip in 0.1 s with a 1 kHz response bandwidth and repeats to ±0.5 mm.
The Prima 1 SDK for Linux on x86_64 and ARM64, the VBTS SDK, Prima 1 Studio for Windows with glove teleoperation, and a URDF model for simulation. The interface, supply voltage and hand side are confirmed with the quotation.
The Prima 1 is fully direct-drive with 22 degrees of freedom, 0.2 N backdrive force and visuo-tactile fingertips, built for experiments and data collection. The Flex 2 combines tendons and linear actuators across 23 degrees of freedom and is rated for millions of cycles in daily work.
Recently Viewed